# python version 1.0

# This module has been generated by smidump 0.2.17. Do not edit.

FILENAME = "../../mibs/ietf/MAU-MIB"

MIB = {
    "moduleName" : "MAU-MIB",

    "MAU-MIB" : {
        "nodetype" : "module",
        "language" : "SMIv2",
        "organization" :    
            """IETF Ethernet Interfaces and Hub MIB
Working Group""",
        "contact" : 
            """WG E-mail: hubmib@hprnd.rose.hp.com
To subscribe: hubmib-request@hprnd.rose.hp.com

       Chair: Dan Romascanu
      Postal: Lucent Technologies
              Atidim Technology Park, Bldg. 3
              Tel Aviv 61131
              Israel
         Tel: +972 3 645 8414, 6458458
         Fax: +972 3 648 7146
      E-mail: dromasca@lucent.com

     Editors: Andrew Smith
      Postal: Extreme Networks, Inc.
              10460 Bandley Drive
              Cupertino, CA 95014
              USA
         Tel: +1 408 579-2821
      E-mail: andrew@extremenetworks.com

              John Flick
      Postal: Hewlett-Packard Company
              8000 Foothills Blvd. M/S 5557
             Roseville, CA 95747-5557
             USA
        Tel: +1 916 785 4018
        Fax: +1 916 785 1199
     E-mail: johnf@rose.hp.com
             Kathryn de Graaf
     Postal: Argon Networks
             25 Porter Road
             Littleton, MA  01460
             USA
        Tel: +1 978 486 0665 x163
        Fax: +1 978 486 9379
     E-mail: kdegraaf@argon.com""",
        "description" :
            """Management information for 802.3 MAUs.

The following reference is used throughout
this MIB module:

[IEEE 802.3 Std] refers to
   IEEE Std 802.3, 1998 Edition: 'Information
   technology - Telecommunications and
   information exchange between systems -
   Local and metropolitan area networks -
   Specific requirements - Part 3: Carrier
   sense multiple access with collision
   detection (CSMA/CD) access method and
   physical layer specifications',
   September 1998.

Of particular interest is Clause 30, '10Mb/s,
100Mb/s and 1000Mb/s Management'.""",
        "revisions" : (
            {
                "date" : "1999-08-24 04:00",
                "description" :
                    """This version published as RFC 2668. Updated
to include support for 1000 Mb/sec
MAUs and flow control negotiation.""",
            },
            {
                "date" : "1997-10-31 00:00",
                "description" :
                    """This version published as RFC 2239.""",
            },
            {
                "date" : "1993-09-30 00:00",
                "description" :
                    """Initial version, published as RFC 1515.""",
            },
        ),
        "identity node" : "mauMod",
    },

    "imports" : (
        {"module" : "SNMPv2-SMI", "name" : "Counter32"},
        {"module" : "SNMPv2-SMI", "name" : "Integer32"},
        {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
        {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
        {"module" : "SNMPv2-SMI", "name" : "NOTIFICATION-TYPE"},
        {"module" : "SNMPv2-SMI", "name" : "OBJECT-IDENTITY"},
        {"module" : "SNMPv2-SMI", "name" : "mib-2"},
        {"module" : "SNMPv2-TC", "name" : "TruthValue"},
        {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
        {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
        {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
        {"module" : "SNMPv2-CONF", "name" : "NOTIFICATION-GROUP"},
    ),

    "typedefs" : {
        "JackType" : {
            "basetype" : "Enumeration",
            "status" : "current",
            "other" : {
                "nodetype" : "namednumber",
                "number" : "1"
            },
            "rj45" : {
                "nodetype" : "namednumber",
                "number" : "2"
            },
            "rj45S" : {
                "nodetype" : "namednumber",
                "number" : "3"
            },
            "db9" : {
                "nodetype" : "namednumber",
                "number" : "4"
            },
            "bnc" : {
                "nodetype" : "namednumber",
                "number" : "5"
            },
            "fAUI" : {
                "nodetype" : "namednumber",
                "number" : "6"
            },
            "mAUI" : {
                "nodetype" : "namednumber",
                "number" : "7"
            },
            "fiberSC" : {
                "nodetype" : "namednumber",
                "number" : "8"
            },
            "fiberMIC" : {
                "nodetype" : "namednumber",
                "number" : "9"
            },
            "fiberST" : {
                "nodetype" : "namednumber",
                "number" : "10"
            },
            "telco" : {
                "nodetype" : "namednumber",
                "number" : "11"
            },
            "mtrj" : {
                "nodetype" : "namednumber",
                "number" : "12"
            },
            "hssdc" : {
                "nodetype" : "namednumber",
                "number" : "13"
            },
            "description" :
                """Common enumeration values for repeater
and interface MAU jack types.""",
        },
    }, # typedefs

    "nodes" : {
        "snmpDot3MauMgt" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26",
        }, # node
        "snmpDot3MauTraps" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.0",
        }, # node
        "dot3RpMauBasicGroup" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1",
        }, # node
        "rpMauTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1",
            "status" : "current",
            "description" :
                """Table of descriptive and status information
about the MAU(s) attached to the ports of a
repeater.""",
        }, # table
        "rpMauEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1",
            "status" : "current",
            "linkage" : [
                "rpMauGroupIndex",
                "rpMauPortIndex",
                "rpMauIndex",
            ],
            "description" :
                """An entry in the table, containing information
about a single MAU.""",
        }, # row
        "rpMauGroupIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.1",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """This variable uniquely identifies the group
containing the port to which the MAU described
by this entry is connected.

Note:  In practice, a group will generally be
a field-replaceable unit (i.e., module, card,
or board) that can fit in the physical system
enclosure, and the group number will correspond
to a number marked on the physical enclosure.

The group denoted by a particular value of this
object is the same as the group denoted by the
same value of rptrGroupIndex.""",
            "reference>" :
                """Reference RFC 2108, rptrGroupIndex.""",
        }, # column
        "rpMauPortIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.2",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """This variable uniquely identifies the repeater
port within group rpMauGroupIndex to which the
MAU described by this entry is connected.""",
            "reference>" :
                """Reference RFC 2108, rptrPortIndex.""",
        }, # column
        "rpMauIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.3",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """This variable uniquely identifies the MAU
described by this entry from among other
MAUs connected to the same port
(rpMauPortIndex).""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.1, aMAUID.""",
        }, # column
        "rpMauType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.4",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"", "name" : "ObjectIdentifier"},
            },
            "access" : "readonly",
            "description" :
                """This object identifies the MAU type.  An
initial set of MAU types are defined above.  The
assignment of OBJECT IDENTIFIERs to new types of
MAUs is managed by the IANA.  If the MAU type is
unknown, the object identifier

unknownMauType OBJECT IDENTIFIER ::= { 0 0 }

is returned.  Note that unknownMauType is a
syntactically valid object identifier, and any
conformant implementation of ASN.1 and the BER
must be able to generate and recognize this
value.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.2, aMAUType.""",
        }, # column
        "rpMauStatus" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.5",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "operational" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "standby" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "shutdown" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "reset" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """The current state of the MAU.  This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state.  Some agents may not
support setting the value of this object to some
of the enumerated values.

The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.

A MAU in the operational(3) state is fully
functional, operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.

A MAU in standby(4) state forces DI and CI to
idle and the media transmitter to idle or fault,
if supported.  Standby(4) mode only applies to
link type MAUs.  The state of
rpMauMediaAvailable is unaffected.

A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
rpMauJabberState and rpMauMediaAvailable objects
when it is in this state.  For an AUI, this
state will remove power from the AUI.

Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would.  The agent is not required to
return the value reset (6).

Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU.""",
        }, # column
        "rpMauMediaAvailable" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.6",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "available" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "notAvailable" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "remoteFault" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "invalidSignal" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "remoteJabber" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "remoteLinkLoss" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "remoteTest" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "offline" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "autoNegError" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """If the MAU is a link or fiber type (FOIRL,
10BASE-T, 10BASE-F) then this is equivalent to
the link test fail state/low light function.
For an AUI or a coax (including broadband) MAU
this indicates whether or not loopback is
detected on the DI circuit.  The value of this
attribute persists between packets for MAU types
AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP.

The value other(1) is returned if the
mediaAvailable state is not one of 2 through 11.

The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.  At power-up or following a
reset, the value of this attribute will be
unknown for AUI, coax, and 10BASE-FP MAUs.  For
these MAUs loopback will be tested on each
transmission during which no collision is
detected.  If DI is receiving input when DO
returns to IDL after a transmission and there
has been no collision during the transmission
then loopback will be detected.  The value of
this attribute will only change during
non-collided transmissions for AUI, coax, and
10BASE-FP MAUs.

For 100Mbps and 1000Mbps MAUs, the enumerations
match the states within the respective link
integrity state diagrams, fig 32-16, 23-12 and
24-15 of sections 32, 23 and 24 of [16].  Any
MAU which implements management of
auto-negotiation will map remote fault
indication to remote fault.

The value available(3) indicates that the link,
light, or loopback is normal.  The value
notAvailable(4) indicates link loss, low light,
or no loopback.
The value remoteFault(5) indicates that a fault
has been detected at the remote end of the link.
This value applies to 10BASE-FB, 100BASE-T4 Far
End Fault Indication and non-specified remote
faults from a system running auto-negotiation.
The values remoteJabber(7), remoteLinkLoss(8),
and remoteTest(9) SHOULD be used instead of
remoteFault(5) where the reason for remote fault
is identified in the remote signaling protocol.

The value invalidSignal(6) indicates that an
invalid signal has been received from the other
end of the link.  InvalidSignal(6) applies only
to MAUs of type 10BASE-FB.

Where an IEEE Std 802.3u-1995 clause 22 MII
is present, a logic one in the remote fault bit
(reference section 22.2.4.2.8 of that document)
maps to the value remoteFault(5), and a logic
zero in the link status bit (reference section
22.2.4.2.10 of that document) maps to the value
notAvailable(4).  The value notAvailable(4)
takes precedence over the value remoteFault(5).

Any MAU that implements management of clause 37
Auto-Negotiation will map the received Remote
Fault (RF1 and RF2) bit values for Offline to
offline(10), Link Failure to remoteFault(5) and
Auto-Negotiation Error to autoNegError(11).""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.4, aMediaAvailable.""",
        }, # column
        "rpMauMediaAvailableStateExits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.7",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of times that
rpMauMediaAvailable for this MAU instance leaves
the state available(3).

Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of rptrMonitorPortLastChange.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.5,
aLoseMediaCounter.
RFC 2108, rptrMonitorPortLastChange""",
        }, # column
        "rpMauJabberState" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.8",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "noJabber" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "jabbering" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """The value other(1) is returned if the jabber
state is not 2, 3, or 4.  The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.

The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.

If the MAU is not jabbering the agent returns
noJabber(3).  This is the 'normal' state.

If the MAU is in jabber state the agent returns
the jabbering(4) value.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.6,
aJabber.jabberFlag.""",
        }, # column
        "rpMauJabberingStateEnters" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.9",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4).  For MAUs of type
dot3MauTypeAUI, dot3MauType100BaseT4,
dot3MauType100BaseTX, dot3MauType100BaseFX and
    all 1000Mbps types, this counter will always
    indicate zero.

    Discontinuities in the value of this counter
    can occur at re-initialization of the
    management system, and at other times as
    indicated by the value of
    rptrMonitorPortLastChange.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.6,
aJabber.jabberCounter.
RFC 2108, rptrMonitorPortLastChange""",
        }, # column
        "rpMauFalseCarriers" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.1.1.10",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of false carrier events
during IDLE in 100BASE-X links.  This counter
does not increment at the symbol rate.  It can
increment after a valid carrier completion at a
maximum rate of once per 100 ms until the next
carrier event.

This counter increments only for MAUs of type
dot3MauType100BaseT4, dot3MauType100BaseTX, and
dot3MauType100BaseFX and all 1000Mbps types.
For all other MAU types, this counter will
always indicate zero.

The approximate minimum time for rollover of
this counter is 7.4 hours.

Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of rptrMonitorPortLastChange.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.10, aFalseCarriers.
RFC 2108, rptrMonitorPortLastChange""",
        }, # column
        "rpJackTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.2",
            "status" : "current",
            "description" :
                """Information about the external jacks attached
to MAUs attached to the ports of a repeater.""",
        }, # table
        "rpJackEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.2.1",
            "status" : "current",
            "linkage" : [
                "rpMauGroupIndex",
                "rpMauPortIndex",
                "rpMauIndex",
                "rpJackIndex",
            ],
            "description" :
                """An entry in the table, containing information
about a particular jack.""",
        }, # row
        "rpJackIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.2.1.1",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "noaccess",
            "description" :
                """This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU (rpMauIndex).""",
        }, # column
        "rpJackType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.1.2.1.2",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"MAU-MIB", "name" : "JackType"},
            },
            "access" : "readonly",
            "description" :
                """The jack connector type, as it appears on the
outside of the system.""",
        }, # column
        "dot3IfMauBasicGroup" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2",
        }, # node
        "ifMauTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1",
            "status" : "current",
            "description" :
                """Table of descriptive and status information
about MAU(s) attached to an interface.""",
        }, # table
        "ifMauEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1",
            "status" : "current",
            "linkage" : [
                "ifMauIfIndex",
                "ifMauIndex",
            ],
            "description" :
                """An entry in the table, containing information
about a single MAU.""",
        }, # row
        "ifMauIfIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.1",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """This variable uniquely identifies the interface
to which the MAU described by this entry is
connected.""",
            "reference>" :
                """RFC 1213, ifIndex""",
        }, # column
        "ifMauIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.2",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """This variable uniquely identifies the MAU
described by this entry from among other MAUs
connected to the same interface (ifMauIfIndex).""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.1, aMAUID.""",
        }, # column
        "ifMauType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.3",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"", "name" : "ObjectIdentifier"},
            },
            "access" : "readonly",
            "description" :
                """This object identifies the MAU type.  An
initial set of MAU types are defined above.  The
assignment of OBJECT IDENTIFIERs to new types of
MAUs is managed by the IANA.  If the MAU type is
unknown, the object identifier

unknownMauType OBJECT IDENTIFIER ::= { 0 0 }

is returned.  Note that unknownMauType is a
syntactically valid object identifier, and any
conformant implementation of ASN.1 and the BER
must be able to generate and recognize this
value.

This object represents the operational type of
the MAU, as determined by either (1) the result
of the auto-negotiation function or (2) if
auto-negotiation is not enabled or is not
implemented for this MAU, by the value of the
object ifMauDefaultType.  In case (2), a set to
the object ifMauDefaultType will force the MAU
into the new operating mode.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.2, aMAUType.""",
        }, # column
        "ifMauStatus" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.4",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "operational" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "standby" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "shutdown" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "reset" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """The current state of the MAU.  This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state.  Some agents may not
support setting the value of this object to some
of the enumerated values.

The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.

The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional, operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.

A MAU in standby(4) state forces DI and CI to
idle and the media transmitter to idle or fault,
if supported.  Standby(4) mode only applies to
link type MAUs.  The state of
ifMauMediaAvailable is unaffected.

A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
ifMauJabberState and ifMauMediaAvailable objects
when it is in this state.  For an AUI, this
state will remove power from the AUI.

Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would.  The agent is not required to
return the value reset (6).

Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU.""",
        }, # column
        "ifMauMediaAvailable" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.5",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "available" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "notAvailable" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "remoteFault" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "invalidSignal" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "remoteJabber" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "remoteLinkLoss" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "remoteTest" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "offline" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "autoNegError" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """If the MAU is a link or fiber type (FOIRL,
10BASE-T, 10BASE-F) then this is equivalent to
the link test fail state/low light function.
For an AUI or a coax (including broadband) MAU
this indicates whether or not loopback is
detected on the DI circuit.  The value of this
attribute persists between packets for MAU types
AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP.

The value other(1) is returned if the
mediaAvailable state is not one of 2 through 11.

The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.  At power-up or following a
reset, the value of this attribute will be
unknown for AUI, coax, and 10BASE-FP MAUs.  For
these MAUs loopback will be tested on each
transmission during which no collision is
detected.  If DI is receiving input when DO
returns to IDL after a transmission and there
has been no collision during the transmission
then loopback will be detected.  The value of
this attribute will only change during
non-collided transmissions for AUI, coax, and
10BASE-FP MAUs.

For 100Mbps and 1000Mbps MAUs, the enumerations
match the states within the respective link
integrity state diagrams, fig 32-16, 23-12 and
24-15 of sections 32, 23 and 24 of [16].  Any
MAU which implements management of
auto-negotiation will map remote fault
indication to remote fault.

The value available(3) indicates that the link,
light, or loopback is normal.  The value
notAvailable(4) indicates link loss, low light,
or no loopback.

The value remoteFault(5) indicates that a fault
has been detected at the remote end of the link.
This value applies to 10BASE-FB, 100BASE-T4 Far
End Fault Indication and non-specified remote
faults from a system running auto-negotiation.
The values remoteJabber(7), remoteLinkLoss(8),
and remoteTest(9) SHOULD be used instead of
remoteFault(5) where the reason for remote fault
is identified in the remote signaling protocol.

The value invalidSignal(6) indicates that an
invalid signal has been received from the other
end of the link.  InvalidSignal(6) applies only
to MAUs of type 10BASE-FB.

Where an IEEE Std 802.3u-1995 clause 22 MII
is present, a logic one in the remote fault bit
(reference section 22.2.4.2.8 of that document)
maps to the value remoteFault(5), and a logic
zero in the link status bit (reference section
22.2.4.2.10 of that document) maps to the value
notAvailable(4).  The value notAvailable(4)
takes precedence over the value remoteFault(5).

Any MAU that implements management of clause 37
Auto-Negotiation will map the received RF1 and
RF2 bit values for Offline to offline(10), Link
Failure to remoteFault(5) and Auto-Negotiation
Error to autoNegError(11).""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.4, aMediaAvailable.""",
        }, # column
        "ifMauMediaAvailableStateExits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.6",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of times that
ifMauMediaAvailable for this MAU instance leaves
the state available(3).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.5,
aLoseMediaCounter.
RFC 2233, ifCounterDiscontinuityTime.""",
        }, # column
        "ifMauJabberState" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.7",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "unknown" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "noJabber" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "jabbering" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """The value other(1) is returned if the jabber
state is not 2, 3, or 4.  The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.

The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.

If the MAU is not jabbering the agent returns
noJabber(3).  This is the 'normal' state.

If the MAU is in jabber state the agent returns
the jabbering(4) value.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.6,
aJabber.jabberFlag.""",
        }, # column
        "ifMauJabberingStateEnters" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.8",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). This counter will always
indicate zero for MAUs of type dot1MauTypeAUI
and those of speeds above 10Mbps.

Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.6,
aJabber.jabberCounter.
RFC 2233, ifCounterDiscontinuityTime.""",
        }, # column
        "ifMauFalseCarriers" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.9",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
            },
            "access" : "readonly",
            "description" :
                """A count of the number of false carrier events
during IDLE in 100BASE-X and 1000BASE-X links.

For all other MAU types, this counter will
always indicate zero. This counter does not
increment at the symbol rate.

It can increment after a valid carrier
completion at a maximum rate of once per 100 ms
for 100BASE-X and once per 10us for 1000BASE-X
until the next CarrierEvent.

Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.10, aFalseCarriers.
RFC 2233, ifCounterDiscontinuityTime.""",
        }, # column
        "ifMauTypeList" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.10",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
The value is a sum which initially takes the
value zero.  Then, for each type capability of
this MAU, 2 raised to the power noted below is
added to the sum. For example, a MAU which has
the capability to be only 10BASE-T would have a
value of 512 (2**9).  In contrast, a MAU which
supports both 10Base-T (full duplex) and
100BASE-TX (full duplex) would have a value of
((2**11) + (2**16)) or 67584.

The powers of 2 assigned to the capabilities are
these:

Power  Capability
  0      other or unknown
  1      AUI
  2      10BASE-5
  3      FOIRL
  4      10BASE-2
  5      10BASE-T duplex mode unknown
  6      10BASE-FP
  7      10BASE-FB
  8      10BASE-FL duplex mode unknown
  9      10BROAD36
 10      10BASE-T  half duplex mode
 11      10BASE-T  full duplex mode
 12      10BASE-FL half duplex mode
 13      10BASE-FL full duplex mode
 14      100BASE-T4
 15      100BASE-TX half duplex mode
 16      100BASE-TX full duplex mode
 17      100BASE-FX half duplex mode
 18      100BASE-FX full duplex mode
 19      100BASE-T2 half duplex mode
 20      100BASE-T2 full duplex mode

If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapability.

This object has been deprecated in favour of
ifMauTypeListBits.""",
        }, # column
        "ifMauDefaultType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.11",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"", "name" : "ObjectIdentifier"},
            },
            "access" : "readwrite",
            "description" :
                """This object identifies the default
administrative baseband MAU type, to be used in
conjunction with the operational MAU type
denoted by ifMauType.

The set of possible values for this object is
the same as the set defined for the ifMauType
object.

This object represents the
administratively-configured type of the MAU.  If
auto-negotiation is not enabled or is not
implemented for this MAU, the value of this
object determines the operational type of the
MAU.  In this case, a set to this object will
force the MAU into the specified operating mode.

If auto-negotiation is implemented and enabled
for this MAU, the operational type of the MAU
is determined by auto-negotiation, and the value
of this object denotes the type to which the MAU
will automatically revert if/when
auto-negotiation is later disabled.

NOTE TO IMPLEMENTORS:  It may be necessary to
provide for underlying hardware implementations
which do not follow the exact behavior specified
above.  In particular, when
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by this object, rather than
continuing to operate at the value earlier
determined by the auto-negotiation function.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.1, aMAUID, and
22.2.4.1.4.""",
        }, # column
        "ifMauAutoNegSupported" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.12",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
            },
            "access" : "readonly",
            "description" :
                """This object indicates whether or not
auto-negotiation is supported on this MAU.""",
        }, # column
        "ifMauTypeListBits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.1.1.13",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Bits",
                    "bOther" : {
                        "nodetype" : "namednumber",
                        "number" : "0"
                    },
                    "bAUI" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "b10base5" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "bFoirl" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "b10base2" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "b10baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "b10baseFP" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "b10baseFB" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "b10baseFL" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "b10broad36" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "b10baseTHD" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "b10baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                    "b10baseFLHD" : {
                        "nodetype" : "namednumber",
                        "number" : "12"
                    },
                    "b10baseFLFD" : {
                        "nodetype" : "namednumber",
                        "number" : "13"
                    },
                    "b100baseT4" : {
                        "nodetype" : "namednumber",
                        "number" : "14"
                    },
                    "b100baseTXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "15"
                    },
                    "b100baseTXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "16"
                    },
                    "b100baseFXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "17"
                    },
                    "b100baseFXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "18"
                    },
                    "b100baseT2HD" : {
                        "nodetype" : "namednumber",
                        "number" : "19"
                    },
                    "b100baseT2FD" : {
                        "nodetype" : "namednumber",
                        "number" : "20"
                    },
                    "b1000baseXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "21"
                    },
                    "b1000baseXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "22"
                    },
                    "b1000baseLXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "23"
                    },
                    "b1000baseLXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "24"
                    },
                    "b1000baseSXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "25"
                    },
                    "b1000baseSXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "26"
                    },
                    "b1000baseCXHD" : {
                        "nodetype" : "namednumber",
                        "number" : "27"
                    },
                    "b1000baseCXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "28"
                    },
                    "b1000baseTHD" : {
                        "nodetype" : "namednumber",
                        "number" : "29"
                    },
                    "b1000baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "30"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapability.

Note that this MAU may be capable of operating
as a MAU type that is beyond the scope of this
MIB.  This is indicated by returning the
bit value bOther in addition to any bit values
for capabilities that are listed above.""",
        }, # column
        "ifJackTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.2",
            "status" : "current",
            "description" :
                """Information about the external jacks attached
to MAUs attached to an interface.""",
        }, # table
        "ifJackEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.2.1",
            "status" : "current",
            "linkage" : [
                "ifMauIfIndex",
                "ifMauIndex",
                "ifJackIndex",
            ],
            "description" :
                """An entry in the table, containing information
about a particular jack.""",
        }, # row
        "ifJackIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.2.1.1",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "noaccess",
            "description" :
                """This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU.""",
        }, # column
        "ifJackType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.2.2.1.2",
            "status" : "current",
            "syntax" : {
                "type" : { "module" :"MAU-MIB", "name" : "JackType"},
            },
            "access" : "readonly",
            "description" :
                """The jack connector type, as it appears on the
outside of the system.""",
        }, # column
        "dot3BroadMauBasicGroup" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3",
        }, # node
        "broadMauBasicTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1",
            "status" : "deprecated",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

Table of descriptive and status information
about the broadband MAUs connected to
interfaces.""",
        }, # table
        "broadMauBasicEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1",
            "status" : "deprecated",
            "linkage" : [
                "broadMauIfIndex",
                "broadMauIndex",
            ],
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

An entry in the table, containing information
about a single broadband MAU.""",
        }, # row
        "broadMauIfIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1.1",
            "status" : "deprecated",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

This variable uniquely identifies the interface
to which the MAU described by this entry is
connected.""",
            "reference>" :
                """Reference RFC 1213, ifIndex.""",
        }, # column
        "broadMauIndex" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1.2",
            "status" : "deprecated",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Integer32",
                    "range" : {
                        "min" : "1",
                        "max" : "2147483647"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

This variable uniquely identifies the MAU
connected to interface broadMauIfIndex that is
described by this entry.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.1, aMAUID.""",
        }, # column
        "broadMauXmtRcvSplitType" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1.3",
            "status" : "deprecated",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "single" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "dual" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

This object indicates the type of frequency
multiplexing/cabling system used to separate the
transmit and receive paths for the 10BROAD36
MAU.

The value other(1) is returned if the split type
is not either single or dual.

The value single(2) indicates a single cable
system.  The value dual(3) indicates a dual
cable system, offset normally zero.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.8,
aBbMAUXmitRcvSplitType.""",
        }, # column
        "broadMauXmtCarrierFreq" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1.4",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

This variable indicates the transmit carrier
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.9,
aBroadbandFrequencies.xmitCarrierFrequency.""",
        }, # column
        "broadMauTranslationFreq" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.3.1.1.5",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

This variable indicates the translation offset
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.5.1.1.9,
aBroadbandFrequencies.translationFrequency.""",
        }, # column
        "dot3MauType" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4",
        }, # node
        "dot3MauTypeAUI" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.1",
            "status" : "current",
            "description" :
                """no internal MAU, view from AUI""",
        }, # node
        "dot3MauType10Base5" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.2",
            "status" : "current",
            "description" :
                """thick coax MAU (per 802.3 section 8)""",
        }, # node
        "dot3MauTypeFoirl" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.3",
            "status" : "current",
            "description" :
                """FOIRL MAU (per 802.3 section 9.9)""",
        }, # node
        "dot3MauType10Base2" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.4",
            "status" : "current",
            "description" :
                """thin coax MAU (per 802.3 section 10)""",
        }, # node
        "dot3MauType10BaseT" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.5",
            "status" : "current",
            "description" :
                """UTP MAU (per 802.3 section 14).
Note that it is strongly recommended that
agents return either dot3MauType10BaseTHD or
dot3MauType10BaseTFD if the duplex mode is
known.  However, management applications should
be prepared to receive this MAU type value from
older agent implementations.""",
        }, # node
        "dot3MauType10BaseFP" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.6",
            "status" : "current",
            "description" :
                """passive fiber MAU (per 802.3 section 16)""",
        }, # node
        "dot3MauType10BaseFB" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.7",
            "status" : "current",
            "description" :
                """sync fiber MAU (per 802.3 section 17)""",
        }, # node
        "dot3MauType10BaseFL" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.8",
            "status" : "current",
            "description" :
                """async fiber MAU (per 802.3 section 18)
Note that it is strongly recommended that
agents return either dot3MauType10BaseFLHD or
dot3MauType10BaseFLFD if the duplex mode is
known.  However, management applications should
be prepared to receive this MAU type value from
older agent implementations.""",
        }, # node
        "dot3MauType10Broad36" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.9",
            "status" : "current",
            "description" :
                """broadband DTE MAU (per 802.3 section 11).
Note that 10BROAD36 MAUs can be attached to
interfaces but not to repeaters.""",
        }, # node
        "dot3MauType10BaseTHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.10",
            "status" : "current",
            "description" :
                """UTP MAU (per 802.3 section 14), half duplex
mode""",
        }, # node
        "dot3MauType10BaseTFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.11",
            "status" : "current",
            "description" :
                """UTP MAU (per 802.3 section 14), full duplex
mode""",
        }, # node
        "dot3MauType10BaseFLHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.12",
            "status" : "current",
            "description" :
                """async fiber MAU (per 802.3 section 18), half
duplex mode""",
        }, # node
        "dot3MauType10BaseFLFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.13",
            "status" : "current",
            "description" :
                """async fiber MAU (per 802.3 section 18), full
duplex mode""",
        }, # node
        "dot3MauType100BaseT4" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.14",
            "status" : "current",
            "description" :
                """4 pair categ. 3 UTP (per 802.3 section 23)""",
        }, # node
        "dot3MauType100BaseTXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.15",
            "status" : "current",
            "description" :
                """2 pair categ. 5 UTP (per 802.3 section 25),
half duplex mode""",
        }, # node
        "dot3MauType100BaseTXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.16",
            "status" : "current",
            "description" :
                """2 pair categ. 5 UTP (per 802.3 section 25),
full duplex mode""",
        }, # node
        "dot3MauType100BaseFXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.17",
            "status" : "current",
            "description" :
                """X fiber over PMT (per 802.3 section 26), half
duplex mode""",
        }, # node
        "dot3MauType100BaseFXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.18",
            "status" : "current",
            "description" :
                """X fiber over PMT (per 802.3 section 26), full
duplex mode""",
        }, # node
        "dot3MauType100BaseT2HD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.19",
            "status" : "current",
            "description" :
                """2 pair categ. 3 UTP (per 802.3 section 32),
half duplex mode""",
        }, # node
        "dot3MauType100BaseT2FD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.20",
            "status" : "current",
            "description" :
                """2 pair categ. 3 UTP (per 802.3 section 32),
full duplex mode""",
        }, # node
        "dot3MauType1000BaseXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.21",
            "status" : "current",
            "description" :
                """PCS/PMA (per 802.3 section 36), unknown PMD,
half duplex mode""",
        }, # node
        "dot3MauType1000BaseXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.22",
            "status" : "current",
            "description" :
                """PCS/PMA (per 802.3 section 36), unknown PMD,
full duplex mode""",
        }, # node
        "dot3MauType1000BaseLXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.23",
            "status" : "current",
            "description" :
                """Fiber over long-wavelength laser (per 802.3
section 38), half duplex mode""",
        }, # node
        "dot3MauType1000BaseLXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.24",
            "status" : "current",
            "description" :
                """Fiber over long-wavelength laser (per 802.3
section 38), full duplex mode""",
        }, # node
        "dot3MauType1000BaseSXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.25",
            "status" : "current",
            "description" :
                """Fiber over short-wavelength laser (per 802.3
section 38), half duplex mode""",
        }, # node
        "dot3MauType1000BaseSXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.26",
            "status" : "current",
            "description" :
                """Fiber over short-wavelength laser (per 802.3
section 38), full duplex mode""",
        }, # node
        "dot3MauType1000BaseCXHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.27",
            "status" : "current",
            "description" :
                """Copper over 150-Ohm balanced cable (per 802.3
section 39), half duplex mode""",
        }, # node
        "dot3MauType1000BaseCXFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.28",
            "status" : "current",
            "description" :
                """Copper over 150-Ohm balanced cable (per 802.3
section 39), full duplex mode""",
        }, # node
        "dot3MauType1000BaseTHD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.29",
            "status" : "current",
            "description" :
                """Four-pair Category 5 UTP (per 802.3 section
40), half duplex mode""",
        }, # node
        "dot3MauType1000BaseTFD" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.4.30",
            "status" : "current",
            "description" :
                """Four-pair Category 5 UTP (per 802.3 section
40), full duplex mode""",
        }, # node
        "dot3IfMauAutoNegGroup" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5",
        }, # node
        "ifMauAutoNegTable" : {
            "nodetype" : "table",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1",
            "status" : "current",
            "description" :
                """Configuration and status objects for the
auto-negotiation function of MAUs attached to
interfaces.""",
        }, # table
        "ifMauAutoNegEntry" : {
            "nodetype" : "row",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1",
            "status" : "current",
            "linkage" : [
                "ifMauIfIndex",
                "ifMauIndex",
            ],
            "description" :
                """An entry in the table, containing configuration
and status information for the auto-negotiation
function of a particular MAU.""",
        }, # row
        "ifMauAutoNegAdminStatus" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.1",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "enabled" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "disabled" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """Setting this object to enabled(1) will cause
the interface which has the auto-negotiation
signaling ability to be enabled.

If the value of this object is disabled(2) then
the interface will act as it would if it had no
auto-negotiation signaling.  Under these
conditions, an IEEE 802.3 MAU will immediately
be forced to the state indicated by the value of
the object ifMauDefaultType.

NOTE TO IMPLEMENTORS:  When
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by the ifMauDefaultType
object, rather than continuing to operate at the
value earlier determined by the auto-negotiation
function.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.2,
aAutoNegAdminState and 30.6.1.2.2,
acAutoNegAdminControl.""",
        }, # column
        "ifMauAutoNegRemoteSignaling" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.2",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "detected" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "notdetected" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value indicating whether the remote end of
the link is using auto-negotiation signaling. It
takes the value detected(1) if and only if,
during the previous link negotiation, FLP Bursts
were received.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.3,
aAutoNegRemoteSignaling.""",
        }, # column
        "ifMauAutoNegConfig" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.4",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "other" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "configuring" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "complete" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "disabled" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "parallelDetectFail" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value indicating the current status of the
auto-negotiation process.  The enumeration
parallelDetectFail(5) maps to a failure in
parallel detection as defined in 28.2.3.1 of
[IEEE 802.3 Std].""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.4,
aAutoNegAutoConfig.""",
        }, # column
        "ifMauAutoNegCapability" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.5",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity.  The value is a sum which initially
takes the value zero.  Then, for each capability
of this interface, 2 raised to the power noted
below is added to the sum. For example, an
interface which has the capability to support
only 100Base-TX half duplex would have a value
of 32768 (2**15).  In contrast, an interface
which supports both 100Base-TX half duplex and
and 100Base-TX full duplex would have a value of
98304 ((2**15) + (2**16)).

The powers of 2 assigned to the capabilities are
these:

Power   Capability
  0       other or unknown
 (1-9)    (reserved)
 10       10BASE-T  half duplex mode
 11       10BASE-T  full duplex mode
 12       (reserved)
 13       (reserved)
 14       100BASE-T4
 15       100BASE-TX half duplex mode
 16       100BASE-TX full duplex mode
 17       (reserved)
 18       (reserved)
 19      100BASE-T2 half duplex mode
 20      100BASE-T2 full duplex mode

Note that interfaces that support this MIB may
have capabilities that extend beyond the scope
of this MIB.
This object has been deprecated in favour of
ifMauAutoNegCapabilityBits""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility.""",
        }, # column
        "ifMauAutoNegCapAdvertised" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.6",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readwrite",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.

Capabilities in this object that are not
available in ifMauAutoNegCapability cannot be
enabled.

This object has been deprecated in favour of
ifMauAutoNegCapAdvertisedBits""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility.""",
        }, # column
        "ifMauAutoNegCapReceived" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.7",
            "status" : "deprecated",
            "syntax" : {
                "type" : { "module" :"", "name" : "Integer32"},
            },
            "access" : "readonly",
            "description" :
                """********* THIS OBJECT IS DEPRECATED **********

A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.

Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
which have capabilities beyond the scope of this
MIB.

This object has been deprecated in favour of
ifMauAutoNegCapReceivedBits""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility.""",
        }, # column
        "ifMauAutoNegRestart" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.8",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "restart" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "norestart" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """If the value of this object is set to
restart(1) then this will force auto-negotiation
to begin link renegotiation. If auto-negotiation
signaling is disabled, a write to this object
has no effect.

Setting the value of this object to norestart(2)
has no effect.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.2.1,
acAutoNegRestartAutoConfig.""",
        }, # column
        "ifMauAutoNegCapabilityBits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.9",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Bits",
                    "bOther" : {
                        "nodetype" : "namednumber",
                        "number" : "0"
                    },
                    "b10baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "b10baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "b100baseT4" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "b100baseTX" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "b100baseTXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "b100baseT2" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "b100baseT2FD" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "bfdxPause" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "bfdxAPause" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "bfdxSPause" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "bfdxBPause" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                    "b1000baseX" : {
                        "nodetype" : "namednumber",
                        "number" : "12"
                    },
                    "b1000baseXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "13"
                    },
                    "b1000baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "14"
                    },
                    "b1000baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "15"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity.  Note that interfaces that support this
MIB may have capabilities that extend beyond the
scope of this MIB.

Note that the local auto-negotiation entity may
support some capabilities beyond the scope of
this MIB.  This is indicated by returning the
bit value bOther in addition to any bit values
for capabilities that are listed above.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility.""",
        }, # column
        "ifMauAutoNegCapAdvertisedBits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.10",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Bits",
                    "bOther" : {
                        "nodetype" : "namednumber",
                        "number" : "0"
                    },
                    "b10baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "b10baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "b100baseT4" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "b100baseTX" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "b100baseTXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "b100baseT2" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "b100baseT2FD" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "bFdxPause" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "bFdxAPause" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "bFdxSPause" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "bFdxBPause" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                    "b1000baseX" : {
                        "nodetype" : "namednumber",
                        "number" : "12"
                    },
                    "b1000baseXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "13"
                    },
                    "b1000baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "14"
                    },
                    "b1000baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "15"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity.

Capabilities in this object that are not
available in ifMauAutoNegCapabilityBits cannot
be enabled.
Note that the local auto-negotiation entity may
advertise some capabilities beyond the scope of
this MIB.  This is indicated by returning the
bit value bOther in addition to any bit values
for capabilities that are listed above.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility.""",
        }, # column
        "ifMauAutoNegCapReceivedBits" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.11",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Bits",
                    "bOther" : {
                        "nodetype" : "namednumber",
                        "number" : "0"
                    },
                    "b10baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "b10baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "b100baseT4" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "b100baseTX" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                    "b100baseTXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "5"
                    },
                    "b100baseT2" : {
                        "nodetype" : "namednumber",
                        "number" : "6"
                    },
                    "b100baseT2FD" : {
                        "nodetype" : "namednumber",
                        "number" : "7"
                    },
                    "bFdxPause" : {
                        "nodetype" : "namednumber",
                        "number" : "8"
                    },
                    "bFdxAPause" : {
                        "nodetype" : "namednumber",
                        "number" : "9"
                    },
                    "bFdxSPause" : {
                        "nodetype" : "namednumber",
                        "number" : "10"
                    },
                    "bFdxBPause" : {
                        "nodetype" : "namednumber",
                        "number" : "11"
                    },
                    "b1000baseX" : {
                        "nodetype" : "namednumber",
                        "number" : "12"
                    },
                    "b1000baseXFD" : {
                        "nodetype" : "namednumber",
                        "number" : "13"
                    },
                    "b1000baseT" : {
                        "nodetype" : "namednumber",
                        "number" : "14"
                    },
                    "b1000baseTFD" : {
                        "nodetype" : "namednumber",
                        "number" : "15"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity.

Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
which have capabilities beyond the scope of this
MIB.  This is indicated by returning the bit
value bOther in addition to any bit values for
capabilities that are listed above.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility.""",
        }, # column
        "ifMauAutoNegRemoteFaultAdvertised" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.12",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "noError" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "offline" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "linkFailure" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "autoNegError" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                },
            },
            "access" : "readwrite",
            "description" :
                """A value that identifies any local fault
indications that this MAU has detected and will
advertise at the next auto-negotiation
interaction for 1000Mbps MAUs.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility.""",
        }, # column
        "ifMauAutoNegRemoteFaultReceived" : {
            "nodetype" : "column",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.5.1.1.13",
            "status" : "current",
            "syntax" : {
                "type" :                 {
                    "basetype" : "Enumeration",
                    "noError" : {
                        "nodetype" : "namednumber",
                        "number" : "1"
                    },
                    "offline" : {
                        "nodetype" : "namednumber",
                        "number" : "2"
                    },
                    "linkFailure" : {
                        "nodetype" : "namednumber",
                        "number" : "3"
                    },
                    "autoNegError" : {
                        "nodetype" : "namednumber",
                        "number" : "4"
                    },
                },
            },
            "access" : "readonly",
            "description" :
                """A value that identifies any fault indications
received from the far end of a link by the
local auto-negotiation entity for 1000Mbps
MAUs.""",
            "reference>" :
                """[IEEE 802.3 Std], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility.""",
        }, # column
        "mauMod" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6",
            "status" : "current",
        }, # node
        "mauModConf" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1",
        }, # node
        "mauModCompls" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.1",
        }, # node
        "mauModObjGrps" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2",
        }, # node
        "mauModNotGrps" : {
            "nodetype" : "node",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.3",
        }, # node
    }, # nodes

    "notifications" : {
        "rpMauJabberTrap" : {
            "nodetype" : "notification",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.0.1",
            "status" : "current",
            "objects" : {
                "rpMauJabberState" : {
                    "nodetype" : "object",
                    "module" : "MAU-MIB"
                },
            },
            "description" :
                """This trap is sent whenever a managed repeater
MAU enters the jabber state.

The agent MUST throttle the generation of
consecutive rpMauJabberTraps so that there is at
least a five-second gap between them.""",
            "reference>" :
                """[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber
notification.""",
        }, # notification
        "ifMauJabberTrap" : {
            "nodetype" : "notification",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.0.2",
            "status" : "current",
            "objects" : {
                "ifMauJabberState" : {
                    "nodetype" : "object",
                    "module" : "MAU-MIB"
                },
            },
            "description" :
                """This trap is sent whenever a managed interface
MAU enters the jabber state.

The agent MUST throttle the generation of
consecutive ifMauJabberTraps so that there is at
least a five-second gap between them.""",
            "reference>" :
                """[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber
notification.""",
        }, # notification
    }, # notifications

    "groups" : {
        "mauRpGrpBasic" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.1",
            "status" : "current",
            "members" : {
                "rpMauGroupIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauPortIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauStatus" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauMediaAvailable" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauMediaAvailableStateExits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauJabberState" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "rpMauJabberingStateEnters" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Basic conformance group for MAUs attached to
repeater ports.  This group is also the
conformance specification for RFC 1515
implementations.""",
        }, # group
        "mauRpGrp100Mbs" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.2",
            "status" : "current",
            "members" : {
                "rpMauFalseCarriers" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for MAUs attached to
repeater ports with 100 Mb/s or greater
capability.""",
        }, # group
        "mauRpGrpJack" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.3",
            "status" : "current",
            "members" : {
                "rpJackType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for MAUs attached to
repeater ports with managed jacks.""",
        }, # group
        "mauIfGrpBasic" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.4",
            "status" : "current",
            "members" : {
                "ifMauIfIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauStatus" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauMediaAvailable" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauMediaAvailableStateExits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauJabberState" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauJabberingStateEnters" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Basic conformance group for MAUs attached to
interfaces.  This group also provides a
conformance specification for RFC 1515
implementations.""",
        }, # group
        "mauIfGrp100Mbs" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.5",
            "status" : "deprecated",
            "members" : {
                "ifMauFalseCarriers" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauTypeList" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauDefaultType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegSupported" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """********* THIS GROUP IS DEPRECATED **********

Conformance group for MAUs attached to
interfaces with 100 Mb/s capability.

This object group has been deprecated in favor
of mauIfGrpHighCapacity.""",
        }, # group
        "mauIfGrpJack" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.6",
            "status" : "current",
            "members" : {
                "ifJackType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for MAUs attached to
interfaces with managed jacks.""",
        }, # group
        "mauIfGrpAutoNeg" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.7",
            "status" : "deprecated",
            "members" : {
                "ifMauAutoNegAdminStatus" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegRemoteSignaling" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegConfig" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapability" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapAdvertised" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapReceived" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegRestart" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """********* THIS GROUP IS DEPRECATED **********

Conformance group for MAUs attached to
interfaces with managed auto-negotiation.

This object group has been deprecated in favor
of mauIfGrpAutoNeg2.""",
        }, # group
        "mauBroadBasic" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.8",
            "status" : "deprecated",
            "members" : {
                "broadMauIfIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "broadMauIndex" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "broadMauXmtRcvSplitType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "broadMauXmtCarrierFreq" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "broadMauTranslationFreq" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """********* THIS GROUP IS DEPRECATED **********

Conformance group for broadband MAUs attached
to interfaces.

This object group is deprecated.  There have
been no reported implementations of this group,
and it was felt to be unlikely that there will
be any future implementations.""",
        }, # group
        "mauIfGrpHighCapacity" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.9",
            "status" : "current",
            "members" : {
                "ifMauFalseCarriers" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauTypeListBits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauDefaultType" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegSupported" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for MAUs attached to
interfaces with 100 Mb/s or greater capability.""",
        }, # group
        "mauIfGrpAutoNeg2" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.10",
            "status" : "current",
            "members" : {
                "ifMauAutoNegAdminStatus" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegRemoteSignaling" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegConfig" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapabilityBits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapAdvertisedBits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegCapReceivedBits" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegRestart" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for MAUs attached to
interfaces with managed auto-negotiation.""",
        }, # group
        "mauIfGrpAutoNeg1000Mbps" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.2.11",
            "status" : "current",
            "members" : {
                "ifMauAutoNegRemoteFaultAdvertised" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
                "ifMauAutoNegRemoteFaultReceived" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Conformance group for 1000Mbps MAUs attached to
interfaces with managed auto-negotiation.""",
        }, # group
        "rpMauNotifications" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.3.1",
            "status" : "current",
            "members" : {
                "rpMauJabberTrap" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Notifications for repeater MAUs.""",
        }, # group
        "ifMauNotifications" : {
            "nodetype" : "group",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.3.2",
            "status" : "current",
            "members" : {
                "ifMauJabberTrap" : {
                    "nodetype" : "member",
                    "module" : "MAU-MIB"
                },
            }, # members
            "description" :
                """Notifications for interface MAUs.""",
        }, # group
    }, # groups

    "compliances" : {
        "mauModRpCompl" : {
            "nodetype" : "compliance",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.1.1",
            "status" : "deprecated",
            "description" :
                """******** THIS COMPLIANCE IS DEPRECATED ********

Compliance for MAUs attached to repeater
ports.
This compliance is deprecated and replaced by
mauModRpCompl2, which corrects an oversight by
allowing rpMauStatus to be implemented
read-only.""",
            "requires" : {
                "mauRpGrpBasic" : {
                    "nodetype" : "mandatory",
                    "module" : "MAU-MIB"
                },
                "mauRpGrp100Mbs" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have 100Mb/s or
greater capability.""",
                },
                "mauRpGrpJack" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have one or more
external jacks.""",
                },
                "rpMauNotifications" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is recommended
for MAUs attached to repeater ports.""",
                },
            }, # requires
        }, # compliance
        "mauModIfCompl" : {
            "nodetype" : "compliance",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.1.2",
            "status" : "deprecated",
            "description" :
                """******** THIS COMPLIANCE IS DEPRECATED ********

Compliance for MAUs attached to interfaces.

This compliance is deprecated and replaced by
mauModIfCompl2.""",
            "requires" : {
                "mauIfGrpBasic" : {
                    "nodetype" : "mandatory",
                    "module" : "MAU-MIB"
                },
                "mauIfGrp100Mbs" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have 100Mb/s
capability.""",
                },
                "mauIfGrpJack" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have one or more
external jacks.""",
                },
                "mauIfGrpAutoNeg" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is mandatory
for MAUs which support managed
auto-negotiation.""",
                },
                "mauBroadBasic" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is mandatory
for broadband MAUs.""",
                },
                "ifMauNotifications" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is recommended
for MAUs attached to interfaces.""",
                },
            }, # requires
        }, # compliance
        "mauModIfCompl2" : {
            "nodetype" : "compliance",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.1.3",
            "status" : "current",
            "description" :
                """Compliance for MAUs attached to interfaces.""",
            "requires" : {
                "mauIfGrpBasic" : {
                    "nodetype" : "mandatory",
                    "module" : "MAU-MIB"
                },
                "mauIfGrpHighCapacity" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have 100Mb/s
or greater capability.""",
                },
                "mauIfGrpJack" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have one or more
external jacks.""",
                },
                "mauIfGrpAutoNeg2" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is mandatory
for MAUs which support managed
auto-negotiation.""",
                },
                "mauIfGrpAutoNeg1000Mbps" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is mandatory
for MAUs which have 1000Mb/s or greater
capability and support managed
auto-negotiation.""",
                },
                "ifMauNotifications" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is recommended
for MAUs attached to interfaces.""",
                },
            }, # requires
            "refinements" : {
                "ifMauStatus" : {
                    "module" : "MAU-MIB",
                    "access" : "readonly",
                    "description" :
                        """Write access is not required.""",
                },
            }, # refinements

        }, # compliance
        "mauModRpCompl2" : {
            "nodetype" : "compliance",
            "moduleName" : "MAU-MIB",
            "oid" : "1.3.6.1.2.1.26.6.1.1.4",
            "status" : "current",
            "description" :
                """Compliance for MAUs attached to repeater
ports.""",
            "requires" : {
                "mauRpGrpBasic" : {
                    "nodetype" : "mandatory",
                    "module" : "MAU-MIB"
                },
                "mauRpGrp100Mbs" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have 100Mb/s or
greater capability.""",
                },
                "mauRpGrpJack" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this optional group is
recommended for MAUs which have one or more
external jacks.""",
                },
                "rpMauNotifications" : {
                    "nodetype" : "optional",
                    "module" : "MAU-MIB",
                    "description" :
                        """Implementation of this group is recommended
for MAUs attached to repeater ports.""",
                },
            }, # requires
            "refinements" : {
                "rpMauStatus" : {
                    "module" : "MAU-MIB",
                    "access" : "readonly",
                    "description" :
                        """Write access is not required.""",
                },
            }, # refinements

        }, # compliance
    }, # compliances

}